MM OM5 12fo MPO Gaa na LC, eriri 12 MTP gaa na LC 0.3m Fan-out Patch Cord

Nkọwa Dị Mkpirikpi:

- Njikọ A:

MPO-12

MTP-12

- Njikọ B: 12 ​​* LC Multimode (Agba agba aja aja na agba ọzọ bụ nhọrọ)

- Ụdị eriri: (koodu agba 12)

Ụdị ọtụtụ OM5 50/125

- Polarity:

Ụdị B (ọrụ gara aga)

Nhọrọ ndị ọzọ: Ụdị A, Ụdị C

- OD eriri: 0.9mm

- Ụdị eriri: tube dị nro

- Ogologo fanout: 0.3m (30cm)

- IL: Mfu Dị Ala nke Ukwuu (0.35dB)

- RL: 35dB

- Ngwa: Panel patch dị elu

 

 


Nkọwa Ngwaahịa

Akara Ngwaahịa

MM OM5 12fo MPO Gaa na LC, eriri 12 MTP gaa na LC 0.3m Fan-out Patch Cord

+ MPO gaa na LC ma ọ bụ MTP gaa na LC, eriri patch fan-out na-ejikọ nnukwu njupụta MPO/MTP netwọk ma ọ bụ transceivers ozugbo na ọdụ ụgbọ mmiri LC dị ala, nke dị iche.

+ Ọ na-ejikọta oghere ma na-eme ka mbugharị ebe data dị mfe site n'ikewa otu ahịrị azụ dị elu nke nwere bandwidth ka ọ bụrụ njikọ nkeonwe a na-achịkwa.

+ Ọnụọgụ eriri: 12fo

+ Ụdị eriri: Multimode OM5 50/125

+ Ụdị njikọ:

MPO Nwoke

Nwoke MTP

Nwanyị MPO

Nwanyị MTP

+ Ụdị Polarity:

Ụdị-A (Na-aga n'ihu)

Ụdị-B (Mgbanwe)

Ụdị C (Obe Ejikọtara Ọnụ)

+ Njikọ A n'akụkụ:

MPO-12

MTP-12

+ Nha njikọ B:

LC multimode

SC ọtụtụ ụdị

ụdị ọtụtụ ST

Ụdị ọtụtụ FC

Ụdị ọtụtụ E2000

+ Ụdị eriri: 0.9mm, LSZH, tube rụrụ arụ

+ Ogologo eriri: 30cm (0.3M)

Eriri Multimode: OM3 vs OM4 vs OM5

+ OM5 fiber, ma ọ bụ Wideband Multimode Fiber (WBMMF), bụ eriri optical dị elu, nke e mere maka ebe data dị elu.

+ Ọ na-akwado ọtụtụ ogologo ebili mmiri (850nm ruo 953nm) iji nye 40G, 100G, na 400G Ethernet n'elu otu eriri eriri, na-ebelata mgbagwoju anya na ọnụ ahịa nke eriri ahụ nke ukwuu.

+ E wuru OM5 maka netwọkụ ụlọ ọrụ na ebe nchekwa data igwe ojii nke chọrọ ijikọta ọnụọgụ eriri.

+ Isi/Mkpuchi: 50/125um, yiri OM3 na OM4.

+ Mgbakwunye Nkewa Wavelength (SWDM): Eriri multimode mbụ e ji SWDM rụọ, nke na-enye ya ohere ibu opekempe ogologo ebili anọ dị iche iche na otu eriri eriri.

+ Isi ihe dị iche n'etiti eriri OM3, OM4, na OM5 multi-mode bụ ikike bandwidth ha, oke nnyefe kachasị, na nkwado maka multiplexing na netwọk dị mkpụmkpụ.

+ Ntụnyere Ndị Dị Mkpa

- eriri OM3: Emebere ya ka ọ dị mfe iji ruo 10Gbps ruo 40Gbps n'ime obere oge ụlọ.

- OM4 eriri: OM3 emelitere nke nwere bandwidth dị elu maka njikọ 40G/100G dị ogologo.

- eriri OM5: Emebere ya kpọmkwem maka obere ebili mmiri nkewa (SWDM) iji belata ọnụọgụ eriri niile.

+ Arụmọrụ teknụzụ:

atụmatụ OM3-300 OM4 OM5
Agba Jaketị Aqua Aqua / Violet Akwụkwọ ndụ akwụkwọ ndụ Lime
Dayameta Isi 50 μm 50 μm 50 μm
Isi mkpuchi 125 μm 125 μm 125 μm
Akwadoro Ogologo Wavelengths 850 nm 850 nm 850 nm ruo 953 nm
Oke Anya Ethernet nke 10G mita 300 mita 550 mita 550
Ogologo Kachasị Elu nke 40G / 100G mita 100 mita 150 mita 150
Nkwado SWDM No No Ee (ọwa anọ)

 

Ngwa

+ Ebe nchekwa data

+ Ebe nchekwa data AI

+ Ebe njikọ njikọ kpakpando

+ Metro, Bank, ...

+ Njikọ Ngwaọrụ-na-Mgbanwe Kpọmkwem

+ Nduzi azụ-na-na-ngwaọrụ

+ Ịkwado Njupụta Dị Elu

Nkọwapụta

Ụdị

Ụdị Otu

Ụdị Otu

Ụdị Ọtụtụ

(APC Polish)

(UPC Polish)

(Pọshịntịn PC)

Ọnụọgụ eriri

8, 12, 24 wdg.

8, 12, 24 wdg.

8, 12, 24 wdg.

Ụdị eriri

G652D,G657A1 wdg.

G652D,G657A1 wdg.

OM1, OM2, OM3, OM4, wdg.

Mfu Ntinye Kachasị Elu

Ndị ọkachamara

Ọkọlọtọ

Ndị ọkachamara

Ọkọlọtọ

Ndị ọkachamara

Ọkọlọtọ

Mfu dị ala

Mfu dị ala

Mfu dị ala

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.60dB

Mfu Nlaghachi

≥60 dB

≥60 dB

NA

Ogologo oge

≥ugboro 500

≥ugboro 500

≥ugboro 500

Okpomọkụ Ọrụ

-40℃~+80℃

-40℃~+80℃

-40℃~+80℃

Ogologo Ule Ule

1310nm

1310nm

1310nm

Nnwale ntinye-ịdọpụta

Ugboro 1000<0.5 dB

Mgbanwe Mmekọrịta

0.5 dB

Ike mgbochi nrụgide

15kgf