24f MPO-LC 24fo OM5 50/125 MTP-LC Fan-out 0.9mm 0.3m Optical Fiber Patch Cord
OM5 MPO-LC MTP-LC Fanout Patch Cord
Eriri patch nke A/ MPO-LC / MTP-LC:
+ MPO gaa na LC ma ọ bụ MTP gaa na LC, eriri patch fan-out na-ejikọ nnukwu njupụta MPO/MTP netwọk ma ọ bụ transceivers ozugbo na ọdụ ụgbọ mmiri LC dị ala, nke dị iche.
+ Ọ na-ejikọta oghere ma na-eme ka mbugharị ebe data dị mfe site n'ikewa otu ahịrị azụ dị elu nke nwere bandwidth ka ọ bụrụ njikọ nkeonwe a na-achịkwa.
+ Ọnụọgụ eriri: 24fo
+ Ụdị eriri: Multimode OM5 50/125
+ Ụdị njikọ:
Nwoke MPO / Nwoke MTP
Nwanyị MPO / Nwanyị MTP
+ Ụdị Polarity:
Ụdị-A (Na-aga n'ihu)
Ụdị-B (Mgbanwe)
Ụdị C (Obe Ejikọtara Ọnụ)
+ Njikọ A n'akụkụ: MPO-24, MTP-24
+ Nha njikọ B: LC multimode
+ Ụdị eriri: 0.9mm, LSZH, tube rụrụ arụ
+ Ogologo eriri: 30cm (0.3M)
B/ Multimode eriri OM5:
+ OM5 eriri bụ eriri anya dị elu, nke e mere maka ebe data dị elu.
+ Ọ na-akwado ọtụtụ ogologo ebili mmiri (850nm ruo 953nm) iji nye 40G, 100G, na 400G Ethernet n'elu otu eriri eriri, na-ebelata mgbagwoju anya na ọnụ ahịa nke eriri ahụ nke ukwuu.
+ E wuru OM5 maka netwọkụ ụlọ ọrụ na ebe nchekwa data igwe ojii nke chọrọ ijikọta ọnụọgụ eriri.
+ Isi/Mkpuchi: 50/125um.
+ Mgbakwunye Nkewa Wavelength (SWDM): Eriri multimode mbụ e ji SWDM rụọ, nke na-enye ya ohere ibu opekempe ogologo ebili anọ dị iche iche na otu eriri eriri.
MPO-LC/MTP-LC Fanout Patch Cord Polarity
+ MPO gaa na LC / MTP gaa na LC ụdị polarity nke eriri patch:
- Ụdị A (Na-aga n'ihu)
Nhazi: Ntụtụ 1 na njikọ MPO na-ejikọ ozugbo na LC leg 1, Ntụtụ 2 na LC leg 2, na ndị ọzọ.
Nhazi njikọ: Nhazi igodo-elu ruo na igodo-ala.
Kachasị Mma Maka: Kaseti modular ma ọ bụ sistemụ nhazi azụ azụ. Ebe ọ bụ na eriri ahụ anaghị atụgharị mgbaama ahụ n'ime, ị ga-eji aka gị gafee eriri patch ahụ n'otu nsọtụ nke ọwa ngwaike iji mezue njikọ Tx-to-Rx.
- Ụdị B (Cross-over / Rollover)
Nhazi: Usoro nhazi nke a tụgharịrị kpamkpam. Ntụtụ 1 na njikọ MPO na-egosi ụkwụ LC ikpeazụ (Leg 12 na sistemụ eriri 12), ebe Ntụtụ 12 na-ejikọ na ụkwụ LC 1.
Nhazi njikọ: Nhazi igodo-elu ruo na igodo-elu.
Kachasị Mma Maka: Ịkwado transceiver ozugbo (dịka ọmụmaatụ, itinye transceiver QSFP+ ma ọ bụ QSFP28 ozugbo n'ime ọdụ ụgbọ mmiri 10G ma ọ bụ 25G SFP nke ọ bụla). Ọ na-ejikwa mgbanwe Tx/Rx n'ime ya na akpaghị aka, yabụ ọ dịghị mkpa ịgafe eriri aka. Nke a bụ nhọrọ polarity kachasị maka njikọ fanout ozugbo.
- Ụdị C (Agbanweela Abụọ)
Nhazi: A na-atụgharị eriri n'usoro n'ime ụzọ abụọ dị n'akụkụ. Tinye maapụ 1 na LC leg 2, Tinye maapụ 2 na LC leg 1, Tinye maapụ 3 na LC leg 4, na Tinye maapụ 4 na LC leg 3.
Nhazi njikọ: Nhazi igodo-elu ruo na igodo-ala.
Kachasị Mma Maka: Nhazi netwọk duplex nke ọtụtụ node ọdịnala. A naghị etinye ya n'ebe data dị elu nke oge a.
Ngwa
+ Ebe nchekwa data nnyefe ọsọ dị elu
+ Ebe nchekwa data AI
+ Ebe njikọ njikọ kpakpando
+ Ebe nchekwa data njikwa Metro,
+ Nnukwu nnukwu ụlọ akụ nke ebe nchekwa data ego na nkeonwe,
+ Njikọ Ngwaọrụ-na-Mgbanwe Kpọmkwem
+ Nduzi azụ-na-na-ngwaọrụ
+ Ịkwado Njupụta Dị Elu
Nkọwapụta
| Ụdị | Ụdị Otu | Ụdị Otu | Ụdị Ọtụtụ | |||
|
| (APC Polish) | (UPC Polish) | (Pọshịntịn PC) | |||
| Ọnụọgụ eriri | 8, 12, 24 wdg. | 8, 12, 24 wdg. | 8, 12, 24 wdg. | |||
| Ụdị eriri | G652D,G657A1 wdg. | G652D,G657A1 wdg. | OM1, OM2, OM3, OM4, wdg. | |||
| Mfu Ntinye Kachasị Elu | Ndị ọkachamara | Ọkọlọtọ | Ndị ọkachamara | Ọkọlọtọ | Ndị ọkachamara | Ọkọlọtọ |
|
| Mfu dị ala |
| Mfu dị ala |
| Mfu dị ala |
|
|
| ≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.60dB |
| Mfu Nlaghachi | ≥60 dB | ≥60 dB | NA | |||
| Ogologo oge | ≥ugboro 500 | ≥ugboro 500 | ≥ugboro 500 | |||
| Okpomọkụ Ọrụ | -40℃~+80℃ | -40℃~+80℃ | -40℃~+80℃ | |||
| Ogologo Ule Ule | 1310nm | 1310nm | 1310nm | |||
| Nnwale ntinye-ịdọpụta | Ugboro 1000<0.5 dB | |||||
| Mgbanwe Mmekọrịta | <0.5 dB | |||||