KCO-Fiver-MTP-MPO-QSFP-Banner-peeji nke 1

24f MPO-LC 24fo OM5 50/125 MTP-LC Fan-out 0.9mm 0.3m Optical Fiber Patch Cord

Nkọwa Dị Mkpirikpi:

- Njikọ A:

MPO-24

MTP-24

- Njikọ B: 24 * LC Multimode (Agba agba aja aja na agba ọzọ bụ nhọrọ)

- Ụdị eriri: (koodu agba 12)

Ụdị ọtụtụ OM5 50/125

- Polarity:

Ụdị A (N'ụzọ kwụ ọtọ)

Ụdị B (Cross-over / Rollover)

Ụdị C (Agbanweela Abụọ)

- OD eriri: 0.9mm

- Ụdị eriri: tube dị nro

- Ogologo fanout: 0.3m (30cm)

- IL: Mfu Dị Ala nke Ukwuu (0.35dB)

- RL: 35dB

- Ngwa: Panel patch dị elu

 

 


Nkọwa Ngwaahịa

Akara Ngwaahịa

OM5 MPO-LC MTP-LC Fanout Patch Cord

Eriri patch nke A/ MPO-LC / MTP-LC:

+ MPO gaa na LC ma ọ bụ MTP gaa na LC, eriri patch fan-out na-ejikọ nnukwu njupụta MPO/MTP netwọk ma ọ bụ transceivers ozugbo na ọdụ ụgbọ mmiri LC dị ala, nke dị iche.

+ Ọ na-ejikọta oghere ma na-eme ka mbugharị ebe data dị mfe site n'ikewa otu ahịrị azụ dị elu nke nwere bandwidth ka ọ bụrụ njikọ nkeonwe a na-achịkwa.

+ Ọnụọgụ eriri: 24fo

+ Ụdị eriri: Multimode OM5 50/125

+ Ụdị njikọ:

Nwoke MPO / Nwoke MTP

Nwanyị MPO / Nwanyị MTP

+ Ụdị Polarity:

Ụdị-A (Na-aga n'ihu)

Ụdị-B (Mgbanwe)

Ụdị C (Obe Ejikọtara Ọnụ)

+ Njikọ A n'akụkụ: MPO-24, MTP-24

+ Nha njikọ B: LC multimode

+ Ụdị eriri: 0.9mm, LSZH, tube rụrụ arụ

+ Ogologo eriri: 30cm (0.3M)

B/ Multimode eriri OM5:

+ OM5 eriri bụ eriri anya dị elu, nke e mere maka ebe data dị elu.

+ Ọ na-akwado ọtụtụ ogologo ebili mmiri (850nm ruo 953nm) iji nye 40G, 100G, na 400G Ethernet n'elu otu eriri eriri, na-ebelata mgbagwoju anya na ọnụ ahịa nke eriri ahụ nke ukwuu.

+ E wuru OM5 maka netwọkụ ụlọ ọrụ na ebe nchekwa data igwe ojii nke chọrọ ijikọta ọnụọgụ eriri.

+ Isi/Mkpuchi: 50/125um.

+ Mgbakwunye Nkewa Wavelength (SWDM): Eriri multimode mbụ e ji SWDM rụọ, nke na-enye ya ohere ibu opekempe ogologo ebili anọ dị iche iche na otu eriri eriri.

MPO-LC/MTP-LC Fanout Patch Cord Polarity

+ MPO gaa na LC / MTP gaa na LC ụdị polarity nke eriri patch:

- Ụdị A (Na-aga n'ihu)

Nhazi: Ntụtụ 1 na njikọ MPO na-ejikọ ozugbo na LC leg 1, Ntụtụ 2 na LC leg 2, na ndị ọzọ.

Nhazi njikọ: Nhazi igodo-elu ruo na igodo-ala.

Kachasị Mma Maka: Kaseti modular ma ọ bụ sistemụ nhazi azụ azụ. Ebe ọ bụ na eriri ahụ anaghị atụgharị mgbaama ahụ n'ime, ị ga-eji aka gị gafee eriri patch ahụ n'otu nsọtụ nke ọwa ngwaike iji mezue njikọ Tx-to-Rx.

- Ụdị B (Cross-over / Rollover)

Nhazi: Usoro nhazi nke a tụgharịrị kpamkpam. Ntụtụ 1 na njikọ MPO na-egosi ụkwụ LC ikpeazụ (Leg 12 na sistemụ eriri 12), ebe Ntụtụ 12 na-ejikọ na ụkwụ LC 1.

Nhazi njikọ: Nhazi igodo-elu ruo na igodo-elu.

Kachasị Mma Maka: Ịkwado transceiver ozugbo (dịka ọmụmaatụ, itinye transceiver QSFP+ ma ọ bụ QSFP28 ozugbo n'ime ọdụ ụgbọ mmiri 10G ma ọ bụ 25G SFP nke ọ bụla). Ọ na-ejikwa mgbanwe Tx/Rx n'ime ya na akpaghị aka, yabụ ọ dịghị mkpa ịgafe eriri aka. Nke a bụ nhọrọ polarity kachasị maka njikọ fanout ozugbo.

- Ụdị C (Agbanweela Abụọ)

Nhazi: A na-atụgharị eriri n'usoro n'ime ụzọ abụọ dị n'akụkụ. Tinye maapụ 1 na LC leg 2, Tinye maapụ 2 na LC leg 1, Tinye maapụ 3 na LC leg 4, na Tinye maapụ 4 na LC leg 3.

Nhazi njikọ: Nhazi igodo-elu ruo na igodo-ala.

Kachasị Mma Maka: Nhazi netwọk duplex nke ọtụtụ node ọdịnala. A naghị etinye ya n'ebe data dị elu nke oge a.

MPO-LC-24-Fiber

Ngwa

+ Ebe nchekwa data nnyefe ọsọ dị elu

+ Ebe nchekwa data AI

+ Ebe njikọ njikọ kpakpando

+ Ebe nchekwa data njikwa Metro,

+ Nnukwu nnukwu ụlọ akụ nke ebe nchekwa data ego na nkeonwe,

+ Njikọ Ngwaọrụ-na-Mgbanwe Kpọmkwem

+ Nduzi azụ-na-na-ngwaọrụ

+ Ịkwado Njupụta Dị Elu

Nkwakọba 3

Nkọwapụta

Ụdị

Ụdị Otu

Ụdị Otu

Ụdị Ọtụtụ

(APC Polish)

(UPC Polish)

(Pọshịntịn PC)

Ọnụọgụ eriri

8, 12, 24 wdg.

8, 12, 24 wdg.

8, 12, 24 wdg.

Ụdị eriri

G652D,G657A1 wdg.

G652D,G657A1 wdg.

OM1, OM2, OM3, OM4, wdg.

Mfu Ntinye Kachasị Elu

Ndị ọkachamara

Ọkọlọtọ

Ndị ọkachamara

Ọkọlọtọ

Ndị ọkachamara

Ọkọlọtọ

Mfu dị ala

Mfu dị ala

Mfu dị ala

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.60dB

Mfu Nlaghachi

≥60 dB

≥60 dB

NA

Ogologo oge

≥ugboro 500

≥ugboro 500

≥ugboro 500

Okpomọkụ Ọrụ

-40℃~+80℃

-40℃~+80℃

-40℃~+80℃

Ogologo Ule Ule

1310nm

1310nm

1310nm

Nnwale ntinye-ịdọpụta

Ugboro 1000<0.5 dB

Mgbanwe Mmekọrịta

0.5 dB

Ike mgbochi nrụgide

15kgf


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a zitere anyị ya