KCO-Fiver-MTP-MPO-QSFP-Banner-peeji nke 1

Nnukwu njupụta MPO Fiber Optic Patch Panel 96fo nwere modulu 4

Nkọwa Dị Mkpirikpi:

- Ọnọdụ ngwa ngwa waya dị oke elu

- Obosara nke sentimita iri na itoolu nkịtị

- Isi 1U 96 dị oke elu na isi 2U 192 dị oke elu

- Igbe modulu MPO ihe ABS dị mfe

- Kaseti MPO nke a na-akpọ pluggable, mara mma mana ọ dị mfe, ntinye ngwa ngwa ma melite mgbanwe na ikike njikwa maka obere ọnụ ahịa nrụnye

– Ngwa ngwa zuru oke maka ntinye eriri na njikwa eriri.

– Nzukọ zuru oke (ebugoro) ma ọ bụ panel efu.


Nkọwa Ngwaahịa

Akara Ngwaahịa

Nkọwa

+ Etiti nkesa optical nke e tinyere na rack (ODF) KCO-MPO-1U-01 bụ ngwaọrụ nke na-akwụsị n'etiti waya optical na ngwa nkwukọrịta optical, yana ọrụ nke ịkekọta, ịkwụsị, ịchekwa na ịtọchi waya optical.

+ Paịpụ pụrụ iche a bụ igbe waya MPO nke e mechiri emechi nke ukwuu, nke dị sentimita iri na itoolu, nke dị elu 1U.

+ Ọ bụ imewe pụrụ iche maka ebe nchekwa data nke panel patch ọ bụla nwere ike itinye ruo isi 96 nke LC.

+ Enwere ike iji ya na ngwa waya dị elu dịka ebe kọmputa, ụlọ kọmputa, na nchekwa data.

+ Mkpuchi elu dị n'ihu na azụ nke a na-ewepụ ewepụ, ntuziaka abụọ a na-adọpụta, bezel ihu nke a na-ewepụ ewepụ, igbe modulu ABS dị fechaa na ngwa teknụzụ ndị ọzọ na-eme ka ọ dị mfe iji na ihe ngosi dị oke njupụta ma ọ dị na eriri ma ọ bụ eriri.

+ Paịpụ a nwere ngụkọta nke tray E-layer, nke ọ bụla nwere okporo ụzọ nduzi aluminom nke onwe ya.

+ A na-etinye igbe modulu MPO anọ na tray ọ bụla, a na-etinyekwa igbe modulu ọ bụla na ihe nkwụnye DLC 12 na isi 24.

Arịrịọ teknụzụ

Data teknụzụ

Data

P/N

KCO-MPO-1U-01-96

ihe

Teepu ígwè

Modulu MPO

Dị

Ihe modulu

Plastik

Ọdụ ụgbọ mmiri modulu

Ọdụ ụgbọ mmiri LC Duplex: 12

Ọdụ ụgbọ mmiri MPO: 2

Ụzọ ntinye modulu

Ụdị agbụchiri

Ụdị eriri

Ụdị Abụ (SM) 9/125

MM (OM3, OM4, OM5)

Ọnụọgụ eriri

8fo/ 12fo / 16fo / 24fo

Mfu ntinye

LC ≤ 0.5dB

LC ≤ 0.35dB

MPO ≤ 0.75dB

MPO ≤ 0.35dB

Mfu nloghachi

LC ≥ 55dB

LC ≥ 25dB

MPO ≥ 55dB

MPO ≥ 25dB

Gburugburu Ebe Obibi

Okpomọkụ ọrụ: -5°C ~ +40°C

Okpomọkụ nchekwa: -25°C ~ +55°C

Iru mmiri dị nso

≤95% (na +40°C)

Nrụgide ikuku

76-106kpa

Nkwụsi ike nke ntinye

≥ugboro 1000

Modulu MPO

Nnukwu njupụta 2U 192fo MTP MPO Fiber Optic Pat
Nnukwu Njupụta 2U 192fo MTP MPO Fiber Optic Pat (2)

Ozi ịtụ ihe

P/N

Nọmba modulu.

Ụdị eriri

Ụdị modulu

Njikọ 1

Njikọ 2

KCO-MPO-1U-01

1

2

3

4

SM

OM3-150

OM3-300

OM4

OM5

12fo

12fo*2

24fo

MPO/APC

MPO SM

MPO OM3

MPO OM4

LC/UPC

LC/APC

LC MM

LC OM3

LC OM4

KCO-MPO-2U-01

1

2

3

4

5

6

7

8

SM

OM3-150

OM3-300

OM4

OM5

12fo

12fo*2

24fo

MPO/APC

MPO SM

MPO OM3

MPO OM4

LC/UPC

LC/APC

LC MM

LC OM3

LC OM4


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a zitere anyị ya