800GBASE 2xDR4/DR8 OSFP Finned Top PAM4 1310nm 500m DOM Dual MPO-12/APC SMF Fiber Optical Transceiver Module

Nkọwa Dị Mkpirikpi:

Ndakọrịta NVIDIA/Mellanox MMS4X00-NM

Cisco OSFP-800G-DR8 dakọtara

Netwọk Juniper dakọtara OSFP-2X400G-DR4-P

Dakọtara H3C OSFP800-800G-DR8-SM1310-DMPO


Nkọwa Ngwaahịa

Akara Ngwaahịa

Nkọwa

+ Ngwa KCO-OSFP-800G-DR8 fiber optic transceiver maka OSFP transceiver bụ inye njikọ dị oke ọsọ, obere oge na ebe data na gburugburu High-Performance Computing (HPC), na-enye ohere njikọ 800 Gigabit Ethernet (800GE) na InfiniBand NDR (Next-gen Data Rate) ruo mita 500 na eriri otu ụdị.

+Ngwaọrụ transceivers eriri optic KCO-OSFP-800G-DR8 na-akwado njikọ breakout maka njikọ 2x400G, 4x200G, ma ọ bụ 8x100G ma dakọtara na ngwaọrụ dịka switches NVIDIA, ihe nkwụnye ConnectX-7, na BlueField-3 DPUs.

+Emebere modulu transceiver optical KCO-OSFP-800G-DR8 fiber optic modulu maka mmepụta Ethernet 800GBASE ruo ogologo njikọ 500m n'elu eriri mode OS2 (SMF) site na iji ogologo 1310nm site na njikọ MTP/MPO-12 APC abụọ.

+Njikwa a nke eriri optic KCO-OSFP-800G-DR8 kwekọrọ na ọkọlọtọ IEEE 802.3ck, IEEE 802.3cu na OSFP MSA. Nlekota nyocha dijitalụ arụnyere n'ime ya (DDM) na-enye ohere ịnweta paramita ọrụ n'oge.

+ A na-eji transceiver KCO-OSFP-800G-DR8 OSFP a nke nwere eriri elu a na-eji eme ihe na swiichi ikuku Ethernet.

+ E gosipụtara ya na obere oge, ike dị ala, na ntụkwasị obi, ọ nwere ike ijikọ elu na usoro ihe owuwu akwụkwọ azụ maka ngwa switch-to-switch, ala maka njikọ switch-top-of-rack na ihe nkwụnye netwọk Ethernet, na/ma ọ bụ na BlueField-3 DPUs na sava kọmputa na sistemụ nchekwa. Ọ bụ ngwọta kacha mma maka ebe nchekwa data HPC, AI, na ebe nchekwa data igwe ojii.

Nkọwapụta

P/N

OSFP-800G-DR8-SM1310

Aha Onye Na-ere Ahịa

KCO

Ihe Nhazi Ụdị

Elu OSFP ejiri okpukpu abụọ mee

Oke Ọkwa Data

850Gbps (8x 106.25Gbps)

Ogologo ebili mmiri

 1310nm

Oke Ogologo Kebul

 mita 500

njikọụdị

MTP/MPO-12 APC abụọ

Ụdị eriri

 SMF

Ụdị Onye Na-ebuga

 EML

Ụdị Nnata

 PIN

Ike TX

 -2.9~4.0dBm

Ike Nnata kacha nta

 -5.9dBm

Mmefu ego ike

 3dB

Ibufe ihe nnata

 4dBm

Oke Oriri Ike

 16.5W

Oke Mbibi

 >3.5dB

Mgbanwe (Ọkụ eletrik)

8x100G-PAM4

Mgbanwe (Nhọrọ)

4x100G-PAM4 abụọ

Teknụzụ Nkwakọ ngwaahịa

 Ngwugwu COB (Chip on Board)

Usoro Mgbanwe

 PAM4

CDR (Mweghachi Elekere na Data)

 TX & RX DSP arụnyere n'ime ya

FEC arụpụtara

 No

Usoro iwu

 OSFP MSA HW Rev 4.1, CMIS Rev 5.0, IEEE 802.3cu-2021, IEEE P802.3ck D2.2

Akwụkwọ ikike

Afọ 5

Ngwa na uru

+ Ebe Nchekwa Data Dị Elu:Modulu KCO-OSFP-800G-DR8 na-enye bandwit dị mkpa maka ijikọ swiitị, sava, na akụrụngwa netwọkụ ndị ọzọ n'ime nnukwu ebe data iji kwado igwe ojii na nnyefe data buru ibu.

+ Kọmputa Arụmọrụ Dị Elu (HPC):Ndị otu HPC chọrọ nnukwu ọsọ nnyefe data maka mgbakọ na mwepụ buru ibu. KCO-OSFP-800G-DR8 na-eme ka njikọ ndị a dị mfe maka nnukwu kọmputa na sistemụ HPC ndị ọzọ.

+ Ethernet na InfiniBand:Ọ na-akwado ma usoro Ethernet na InfiniBand, na-enye ọtụtụ ohere maka mkpa netwọk dị iche iche n'ime ebe data.

+ Ike mgbanwe breakout:KCO-OSFP-800G-DR8 nke ọkọlọtọ DR8 na-enye ohere ka modulu ahụ rụọ ọrụ dị ka otu njikọ 800G ma ọ bụ "kewaa" n'ime ọtụtụ njikọ dị ala (2x400G, 4x200G, ma ọ bụ 8x100G), na-ejikọ na ngwaọrụ dị iche iche dị ka NICs ma ọ bụ DPUs.

+Eriri Ụdịdị Otu-Ogologo (SMF):Site na iji eriri otu ụdị, ọkọlọtọ DR8 na-akwado njikọ ruo mita 500, na-enye njikọ siri ike n'ebe dị anya n'ime ụlọ ọrụ.

QSFP-DR8-800G
Ngwa KCO-OSFP-800G-DR8

  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a zitere anyị ya