Ibe ọkọlọtọ

1.25Gb/s 1310nm Otu onye ntụgharị SFP

Nkọwa dị mkpirikpi:

Ndị transceivers nke obere Ụdị Factor Pluggable (SFP) dakọtara na Agreement Multi-Sourcing (MSA). Transceiver nwere akụkụ anọ: onye ọkwọ ụgbọ ala LD, amplifier na-amachi, laser FP na onye nchọpụta foto PIN. Data modul jikọtara ruo 20km na 9/125um fiber mode single mode.

Enwere ike gbanyụọ mmepụta ngwa anya site na ntinye echiche TTL dị elu nke Tx Disable. Emere Tx Fault iji gosi mmebi nke laser ahụ. A na-enye mmepụta ihe ngosi (LOS) iji gosi mfu nke ntinye anya mgbama nke nnata ma ọ bụ ọnọdụ njikọ ya na onye mmekọ.


Nkọwa ngwaahịa

Mkpado ngwaahịa

Njirimara ngwaahịa

+ Njikọ data ruru 1.25Gb/s
+ FP laser transmitter na PIN foto-achọpụta
+ Ruo 20km na 9/125µm SMF
+ akara ukwu SFP na-ekpo ọkụ
+ Duplex LC/UPC ụdị pluggable ngwa anya interface
+ Mgbasa ike dị ala
+ Mkpuchi ọla, maka EMI dị ala
+ RoHS dabara na enweghị ụzọ
+ Otu ike + 3.3V
+ Dabara na SFF-8472
+ Ọnọdụ okpomọkụ na-arụ ọrụ
Azụmahịa: 0°C ruo +70°C
Agbatịpụrụ: -10°C ruo +80°C

Ngwa

+ Gbanwee gaa na interface mgbanwe

+ Gigabit Ethernet

+ Ngwa azụ ụgbọ elu gbanwere

+ Ihe ntanetị / ihe nkesa

+ Njikọ ngwa anya ndị ọzọ

Ịtụ ozi

Nọmba akụkụ ngwaahịa

Ọnụego data

(Mbps)

Mgbasa ozi

Ogologo ogologo

(nm)

Mbufe

Ogologo (km)

Oke okpomọkụ (Tcase) (℃)

KCO-SFP-1.25-SM-20C

1250

Otu mode eriri

1310

20

0 ~ 70

azụmahịa

KCO-SFP-1.25-SM-20E

1250

Otu mode eriri

1310

20

-10-80

gbatịa

KCO-SFP-1.25-SM-20A

1250

Otu mode eriri

1310

20

-40-85

ulo oru

Nkọwa Pin

Ntụtụ

Akara

Aha/Nkọwa

IHE

1

VEET

Ground Transmitter (Nke a na-ahụkarị na ala nnata)

1

2

TFAULT

Mmejọ nnyefe.

3

TDIS

Gbanyụọ nnyefe. Agbanyụrụ mmepụta laser n'elu ma ọ bụ mepere emepe.

2

4

MOD_DEF(2)

Nkọwa Module 2. Data akara maka Oghere Usoro NJ.

3

5

MOD_DEF(1)

Nkọwa Module 1. Ahịrị elekere maka Oghere Usoro NJ.

3

6

MOD_DEF(0)

Nkọwa Module 0. Gburugburu n'ime modul.

3

7

Họrọ Họrọ

Enweghị njikọ achọrọ

4

8

LOS

Ọnwụ nke akara ngosi. Logic 0 na-egosi ọrụ nkịtị.

5

9

VEER

Ala nnata (Nke a na-ahụkarị na Ground Transmitter)

1

10

VEER

Ala nnata (Nke a na-ahụkarị na Ground Transmitter)

1

11

VEER

Ala nnata (Nke a na-ahụkarị na Ground Transmitter)

1

12

RD-

Ndị nnata tụgharịrị DATA. AC jikọtara

13

RD+

Ndị nnata na-abụghị DATA apụọ. AC jikọtara

14

VEER

Ala nnata (Nke a na-ahụkarị na Ground Transmitter)

1

15

VCCR

Nkwanye ike nnata

16

VCCT

Nnyefe Ike

17

VEET

Ground Transmitter (Nke a na-ahụkarị na ala nnata)

1

18

TD+

Mbufe DATA anaghị atụgharị n'ime AC jikọtara.

19

TD-

Mbugharị atụgharịrị DATA n'ime AC Ejikọtara.

20

VEET

Ground Transmitter (Nke a na-ahụkarị na ala nnata)

1

ndetu:
1.Circuit ala bụ internally dịpụrụ adịpụ na chassis ala.
2.Laser mmepụta nwere nkwarụ na TDIS>2.0V ma ọ bụ meghere, nyeere na TDIS <0.8V.
3. Kwesịrị wetara elu na 4.7k - 10kohms na nnabata osisi ka a voltaji n'etiti 2.0V na 3.6V.MOD_DEF (0) akwusila akara ala na-egosi modul na-pluged na.
4.Nke a bụ ntinye nhọrọ nke a na-eji na-achịkwa bandwit nke nnata maka ndakọrịta na ọnụọgụ data dị iche iche (yikarịrị Fiber Channel 1x na 2x Rates) .Ọ bụrụ na emejuputa ya, a ga-etinye ntinye n'ime ya na> 30kΩ resistor. Ntinye kwuru bụ:
- Dị ala (0 - 0.8V): Bandwit belatara
- (> 0.8, <2.0V): Enweghị nkọwa
- Elu (2.0 - 3.465V): bandwit zuru oke
- Mepee: bandwit belatara
5.LOS bụ oghe mkpokọta mmepụta kwesịrị wetara elu na 4.7k - 10kohms na nnabata osisi ka a voltaji n'etiti 2.0V na 3.6V. Logic 0 na-egosi ọrụ nkịtị; mgbagha 1 na-egosi ọnwụ nke mgbaama.

Onyonyo2. Kwuo na ngọngọ Njikọ na bọọdụ nnabata

Nkọwapụta igwe (Nkeji: mm)

Nkọwapụta igwe (Unit mm)
Ndepụta ndakọrịta SFP
KCO 1.25G SFP

  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya